• DSP based Sine Wave Output EUROPOWER Sine Wave UPS has a DSP based circuit that increases the efficiency and accuracy of the UPS. This technology makes possible a high level of internal UPS management and generates a Sine Wave output.
  • Auto Reset EUROPOWER Sine Wave UPS has auto - reset Function in case of Overload short Circuit. It will reset itself automatically and will make 8 attempts for Overload and 4 attempts for Short Circuit. Otherwise it will shut off and you will have to reset the UPS manually by turning ON/OFF switch on its front panel.
  • Protection Circuit The EUROPOWER Sine Wave UPS is protected from low battery voltage and over current conditions. When the UPS senses one of these situation. It will protect itself by disconnecting from the load, and will signal an error condition by displaying along with the buzzer.
  • State-of-the-art DSP based Technology The technology used in EUROPOWER Sine Wave UPS is DSP based technology that uses Auto sense intelligent Control (ASIC).ASIC technology gives maximum power and back up time. DSP monitors the output level and battery voltage and adjust the amplitude and wave shape of the sine wave according to that. The DSP also corrects the power factor while battery charging.
  • Automatic Low Battery Cutout (LBCO) The EUROPOWER Sine Wave UPS protects your batteries from damage caused by over-discharging. By automatically shutting itself off when battery voltage falls to a preset level. This features is called the low battery cutout. The EUROPOWER Sine Wave UPS comes from the factory with the LBCO voltage set at 10 volts per battery.
  • Automatic High Battery Cutout When Battery voltage rises above 14.4 volts per battery, the charger stops its normal charging and comes to the trickle mode so as to take care of the self-discharging of the battery. The charger automatically resumes operation when battery voltage drops below 13.7 volts per battery.
  • Over Current Cutout EUROPOWER Sine Wave UPS is protected from over current Condition. When the load being run demands more current then the Static UPS will shutdown automatically along with the LED Indication.
  • Battery Type Optimisation EUROPOWER Sine Wave UPS is designed to prevent damage and Extend life of your batteries by regulating the charging voltage and Duration. To do this, the static UPS must be configured for the type of Batteries in the system.
  • Automatic High Battery Cutout When Battery voltage rises above 14.4 volts per battery, the charger stops its normal charging and comes to the trickle mode so as to take care of the self-discharging of the battery. The charger automatically resumes operation when battery voltage drops below 13.7 volts per battery.
  • Charge Rate Regulation Batteries can overheat if the charge rate is too high. EUROPOWER UPS protects your batteries by limiting the charging Current, so that the regulation can adjust the charging current to the optimum level.
  • Volts AC Dropout EUROPOWER UPS monitors the voltage of the AC Power passing through to the charger and AC loads. When AC voltage Falls below the present level, the static UPS automatically transfer from AC to DC power (i.e. it comes to invert mode).This dropout voltage is Factory present at 90-110 volts. So when the AC voltage drops to 90- 110 volts, the static UPS automatically transfers from AC to DC power. It will revert to mains with a hysteresis of 20V.
  • Reduces UPS’s Power Consumption IN EUROPOWER the circuity design reduces Power intake of the static UPS whtn battery is in trickle charge mode And evaporation of battery electrolyte is also minimized.